72 410a Manual

  1. Download TENMA 72-410A DIGITAL MULTIMETER service manual & repair info for electronics experts. Service manuals, schematics, eproms for electrical technicians. This site helps you to save the Earth from electronic waste! TENMA 72-410A DIGITAL MULTIMETER. Type: (PDF) Size 439.1 KB.
  2. Manual: Part Number: 72-2104A Beacon 410A, four channel controller (no sensor) 72-2104A-01 Beacon 410A, four channel controller with battery charger (no sensors.

Tappi versus iso brightness scale chart. OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures than R-22,” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A. View & download of more than 135 Tenma PDF user manuals, service manuals, operating guides. Power Supply, Multimeter user manuals, operating guides & specifications. R410A February 2018 R410A Outdoor unit. This service manual describes service data of the outdoor units. SUZ-KA18NA 3 lb. 0 1.08 3.24 5.40 7.56 9.72 11.

Tenma 72 410a Manual

    • Fourth hose to enable connection to hi-/lo-sides, refrigerant tank and recovery unit or vacuum pump for diagnostics, evacuation and charging without switching hoses
    • 3/8″ Vacuum port for use with larger hose to cut evacuation time by up to 33% (all other fittings are 1/4″)
    • Large, easy-to-read 3-1/8″ (90 mm) steel case red and blue, 1% accuracy (Class 1) gauges
    • Front access for easy field recalibration
    • Double “O” ring piston for reliability and long service life
    • Exclusive 100 mesh filter in-line on all flare fittings helps keep out particulate material and extend the life of the seats
    • Contoured easy-grip handles for positive control; color-coded for ready identification
    • Sight glass to easily view refrigerant movement and condition during charging and recovery
    • Optional protective gauge boots available
    • Heavy duty hook won’t pull out
    • Also available with 3-1/2″ (80 mm) red and blue liquid-filled gauges
    • Manifold and hose holder fittings 1/4″-3/8″-1/4″-1/4″ unless otherwise identified
    • Made in the USA
  • Quick Select Tool
    Degree
    Refrigerant
    UPC#Description
    °F and °C (Fahrenheit and Celsius)
    4991349914 With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, kPa/psi, R32/R410A – °F and °C
    49914Manifold only with 5/16″-3/8″-5/15″-5/16″ anchor and service fittings, R/B gauges, kPa/psi, R32/R410A – °F and °C
    49915Manifold only with 5/16″-3/8″-1/4″-5/16″ anchor fittings and 1/4″-3/8″-1/4″-1/4″ service fittings, R/B gauges, kPa/psi, R32/R410A, °F and °C
    49922Manifold only, liquid gauges, bar/psi, R22 – °F and °C
    49925With 60″ PLUS II™ RYB and 3/8″ x 45°, liquid gauges, bar/psi, R22 – °F and °C
    49960With 60″ PLUS II™ compact ball valve RYB and 3/8″ x 40°, R/B gauges, bar/psi, R32/R410A – °F and °C
    49962Manifold only, R/B gauges, bar/psi, R32/R410A – °F and °C
    49964Manifold only with 5/16-3/8-5/16-5/16″ fittings, R/B gauges, bar/psi, R32/410A – °F and °C
    49965With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, bar/psi, R32/R410A – °F and °C
    49966Manifold only with 1/4″ fittings, R/B gauges, bar/psi, R32/410A – °F and °C
    49971Heat pump manifold only, 1/4×5/16×1/4 hose holder fittings, R410A – °F and °C
    49982Manifold only, liquid gauges, bar/psi, R410A – °F and °C
    °F (Fahrenheit)
    49907Manifold only, R/B gauges, bar/psi, R448A/449A/452A – °F
    49973Manifold only, liquid gauges, psi, R22/410A – °F
    49977With 60″ PLUS II™ RYB and 3/8″ x 45°, liquid gauges, R22/410A – °F
    49963Manifold only, R/B gauges, psi, R22/404A/410A – °F
    49967With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, psi, R22/404A/410A – °F
    49968With 60″PLUS II™ compact ball valve RYB and 3/8″ x 45°, R/B gauges, psi, R22/404A/410A – °F
    49283*Manifold only, R/B gauges, psi, R22/404A/410A – °F
    49983Manifold only, R/B gauges, psi, R22/134a/404A – °F
    49987With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, psi, R22/134a/404A – °F
    49993Manifold only, liquid gauges, R22/134a/404A – °F
    49997With 60″ PLUS II™ RYB and 3/8″ x 45°, liquid gauges, psi, R22/134a/404A – °F
    49932Manifold only, R/B gauges, psi, R134a/404A/407C – °F
    49935With 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, psi, R134a/404A/407C – °F
    49952Manifold only, liquid gauges, psi, R134a/404A/407C – °F
    49955With 60″ PLUS II™ RYB and 3/8″ x 45°, liquid gauges, psi, R134a/404A/407C – °F
    49900With 72″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, psi, R417A/422A/422D – °F
    °C (Celsius)
    49901Manifold only, R/B gauges, bar/psi, R448A/449A/452A – °C
    49916Manifold only, R/B gauges, bar/psi, R12/22/502 – °C
    49933Manifold only, R/B gauges, bar/psi, R22/134a/404A – °C
    49912Manifold only, R/B gauges, kPa/psi, R22/134a/404A – °C
    4991149912 with 60″ PLUS II™ RYB and 3/8″ x 45°, R/B gauges, kPa/psi, R22/134a/404A – °C
    49931Manifold only, R/B gauges, bar/psi, R134a/404A/407F – °C
    49934Manifold only, no sight glass, R/B gauges, bar/psi, R134a/404A/407F – °C
    49936Manifold only, R/B gauges, bar/MPa, R134a/404A/407C – °C
    49956Manifold only, R/B gauges, bar/psi, R134a/404A/407C – °C
    49972No sight glass; 800 psi both gauges; bar/psi
    *49283 comes standard with certified gauges.
    Rebuild Kit
    41082TITAN 4-Valve Rebuild Kit

Why Do I need R-410a Certification?

Although R-410A certification is not yet mandatory, it is becoming a common requirement for many companies’ employees. It is important to note that there are significant liabilities associated with not having this certification, as R410-A operates at much higher pressures than R-22 and is not safe to use in the same operating systems. The use of R410-A will always require some change in the system design. Additionally, failure to obtain R410-A certification represents a potential loss of business to technicians, as the use of R-410A is on the rise. Intel gm45 windows 10 driver.

What is the exam like?

Tenma 72 410a Manual

The R-410a Certification Examination is an open book exam that consists of 25 multiple choice questions. You must receive a score of 18 or 72% or more to pass. The exam is FREE. If you wish to receive a R-410a Certification Card, Wall Certificate and letter of accomplishment you may purchase one at the end of completing the exam with proof TypeII or Universal Section 608 Certification . You can download REPA’s R-410a manual for free on the link below.

Manual

Tenma 72-410a Manual

Click Here to Download Manual

Click Here to Take The Test